Tiger's Milk Bryanston, Johannesburg
Full-service casual dining restaurant and bar. Johannesburg, South Africa.
Reported, from the site's interval-monitored record
Measured, interval data
Measured, per measure
Figures from named sites, before solar. Results vary by site.
A busy kitchen and bar on long trading hours
A full-service restaurant with a bar carries a long trading day and a wide menu. Extraction runs whenever the kitchen is open, hot passes stay hot between orders, and the shisha stoves stay lit through the evening. Each of those loads is small on its own and constant across every hour the site is open, which is exactly the profile that a monthly bill hides.
The site could not accept anything that slowed service, changed the food or asked the floor staff to remember a new routine. Every measure had to run itself.
700 kWh a day, recorded rather than estimated
The baseline is the site's own interval-monitored record: about 700 kWh of electricity a day before the service packs were installed, with the same record continuing afterwards. Because the circuits were monitored on both sides of the work, the service-pack figures on this page are measurements rather than estimates, and the whole-site figure is read from the same daily record.
Three service packs, no change to the menu
- Ventilation on demand on the kitchen extraction and supply-air fans, so fan speed follows the cooking load instead of running at full speed all day.
- One-shot rundown timers on the hot passes, so a pass that has been left on turns itself off.
- One-shot rundown timers on the shisha stoves, on the same principle.
The record lists ventilation on demand and rundown timers as the interventions. Measures reported elsewhere for this brand are not part of this record and are not claimed here.
Before and after, with the proof label for each line
| Measure | Before | After | Proof label |
|---|---|---|---|
| Daily electricity, whole site | 700 kWh a day | About 400 kWh a day, a fall of 43% | Reported, from the site's interval-monitored record |
| Extraction and supply-air fans | 80 kWh a day | 13 kWh a day, an 84% reduction, 24-month payback | Measured, interval data |
| Hot passes | Baseline, before rundown timers | 57% measured reduction with rundown timers | Measured |
| Shisha stoves | 20 kWh a day | 10 kWh a day, a 50% reduction with rundown timers, 20-month payback | Measured |
The whole-site figure and the service-pack figures carry different proof labels and are never collapsed into one word. Where the record publishes no before-and-after pair for a system, the before column names the baseline condition rather than a figure.
Measurement methodology
The whole-site figure is read from the site's interval-monitored daily electricity record, before and after the service packs. It is reported from that record: it is not an independently verified result, and it is not adjusted for trading hours, activity or weather. The three service-pack figures are measured on the circuits themselves, which is why they carry a measured label and the whole-site figure does not.
How comparable work is funded
This project predates the structure. Comparable work today needs no upfront capital: a Finance Partner funds approved projects and you repay it from the saving. Any finance solution is provided under a separate customer agreement with a Finance Partner and remains subject to credit approval.
Twenty to twenty-four months, measure by measure
The individual measures paid back in 20 to 24 months: 24 months on the extraction and supply-air fans and 20 months on the shisha stoves. The record values the measures at more than R380,000 (ZAR) a year. No whole-site payback figure is published for this site, because the record does not contain one.
Your Operation Keeps Running
Installed outside service hours. Local override on every system. No extra work for your staff. The full commitments
Prove it at two of your own sites
Send the bills for two sites. We come back with the case.
What sits behind these numbers
The record behind this page is the site's interval-monitored daily electricity record and the service-pack measurements taken from it. It is the strongest measured whole-site record in our team's set. The whole-site figure is reported from that record and is not described as verified. The three service-pack figures are measured on the circuits. The annual value is stated in rand, as the record states it, and is not converted.
Results for another site will differ.
Delivered by the Enspara team, before Enspara was founded in 2026.